Page #10 |
INSTALLATION MANUAL |
STEP 4: PAGE 1 OF 6 |


The Curved Eave Header & Attachment Channels have pre-punched holes for the proper placement of the Rafters 4.1 A & B. The Rafters should be the exact lengths needed for the projection of the Sunroom. The rafters may be trimmed if the back wall is uneven. Rafters should be placed on the Curved eave header, aligned with the pre-punched holes & inserted into the Attachment Channel at the corresponding pre-punched holes. Attach the Rafter to the Header Beam with #14 x 1" Tek Screws, plumb the front wall & secure to the Attachment Channel. Repeat this until all Rafters are in Place.